特点 :
高效率,高可靠
全球适用AC输入电源
低泄漏电流<0.5mA
100%满负荷烧机测试
保护特性:短路/过载/过压/过温
空气冷却
工作频率100KHz
外壳编号:H012
2年保质期
尺寸: 107*61*28mm (L*W*H)
|
型号
|
OTPD-25-3.3
|
OTPD-25-5
|
OTPD-25-7.5
|
OTPD-25-12
|
OTPD-25-13.5
|
OTPD-25-15
|
OTPD-25-24
|
OTPD-25-27
|
OTPD-25-48
|
| 输出 |
直流输出电压 |
3.3V
|
5V
|
7.5V
|
12V
|
13.5V
|
15V
|
24V
|
27V
|
48V
|
| 输出电压容差 |
±3.0%
|
±2%
|
±2%
|
±2%
|
±2%
|
±2%
|
±2%
|
±2%
|
±2%
|
| 额定输出电流 |
5A
|
5A
|
3.3A
|
2.1A
|
1.9A
|
1.7A
|
1A
|
0.9A
|
0.5A
|
| 输出电流范围 |
0-5A
|
0-5A
|
0-3.3A
|
0-2.1A
|
0-1.9A
|
0-1.7A
|
0-1A
|
0-0.9A
|
0-0.5A
|
| 输出功率 |
16.5W
|
25W
|
24.8W
|
25.2W
|
25.7W
|
25.5W
|
24W
|
24.3W
|
24W
|
| 纹波及噪音 |
80mVp-p
|
80mVp-p
|
80mVp-p
|
100mVp-p
|
100mVp-p
|
100mVp-p
|
240mVp-p
|
240mVp-p
|
350mVp-p
|
| 启动、上升、保持时间 |
200ms, 20ms, 100ms /230VAC200ms, 30ms, 20ms /115VAC 满载 |
| 输入 |
输入电压范围 |
85~264VAC47~63Hz ;120~370VDC |
| 交流输入电流 |
0.6A/115VAC0.4A/230VAC |
| 效率 |
66% |
74% |
76% |
78% |
78% |
78% |
79% |
79% |
79% |
| 冲击电流 |
冷启动36A/230VAC |
| 漏电流 |
<0.5 mA/240VAC |
| 保护特性 |
过载保护 |
>105%,打嗝模式,自动恢复 |
| 过电压保护 |
115%-135% 切断输出,重新启动 |
| 高温保护 |
U1≥135℃时,切断输出,自动恢复 |
| 环境 |
工作温度、湿度 |
-10℃~+60℃;20%~90 %RH |
| 保存温度、湿度 |
-20℃~+85℃;10%~95 %RH |
| 抗震性 |
10~500Hz,2G 10min./1周期,时长60分钟,各轴 |
| 安全 |
耐压性 |
输入输出间:3KVAC输入与地:1.5KVAC输出与地:0.5KVAC |
| 绝缘电阻 |
输入输出间,输入与地,输出与地:100M Ohms / 500VDC |
| 符合标准 |
安全标准 |
符合UL60950-1, TUV EN60950-1 |
| EMC标准 |
符合EN55022,EN61000-3-2,-3,EN61000-4-2,3,4,5 |
| 其它 |
重量 |
0.14Kg |
| 包装 |
96pcs/15Kg/1.3CUFT |
| 备注 |
1.所有参数在未特别指明时,都是在230VAC电压输入,额定负载和25℃条件下测量所得值。
2.纹波和噪声电压是在20MHz带宽示波器带12英寸双绞线末端加0.1μ和47μ电容时测得。
3.容差是电压设定误差、电压调整率和电流调整率之总和。
4.本电源考虑做为一个器件安装在最终设备上,该设备必须重新确认它的EMC指标。
|
外形及安装尺寸见下图:
.jpg)
|